smartctl 7.4 2023-08-01 r5530 [x86_64-linux-6.12.86+deb13-amd64] (local build) Copyright (C) 2002-23, Bruce Allen, Christian Franke, www.smartmontools.org === START OF INFORMATION SECTION === Device Model: VR0120GEJXL Serial Number: BTWM73651EPF120B LU WWN Device Id: 5 5cd2e4 14df734db Firmware Version: 4IWTHPG0 User Capacity: 120,034,123,776 bytes [120 GB] Sector Sizes: 512 bytes logical, 4096 bytes physical Rotation Rate: Solid State Device Form Factor: 2.5 inches TRIM Command: Available, deterministic, zeroed Device is: Not in smartctl database 7.3/5528 ATA Version is: ACS-2 T13/2015-D revision 3 SATA Version is: SATA 2.6, 6.0 Gb/s (current: 6.0 Gb/s) Local Time is: Mon Apr 13 19:38:39 2026 UTC SMART support is: Available - device has SMART capability. SMART support is: Enabled === START OF READ SMART DATA SECTION === SMART overall-health self-assessment test result: PASSED General SMART Values: Offline data collection status: (0x00) Offline data collection activity was never started. Auto Offline Data Collection: Disabled. Self-test execution status: ( 0) The previous self-test routine completed without error or no self-test has ever been run. Total time to complete Offline data collection: ( 0) seconds. Offline data collection capabilities: (0x79) SMART execute Offline immediate. No Auto Offline data collection support. Suspend Offline collection upon new command. Offline surface scan supported. Self-test supported. Conveyance Self-test supported. Selective Self-test supported. SMART capabilities: (0x0003) Saves SMART data before entering power-saving mode. Supports SMART auto save timer. Error logging capability: (0x01) Error logging supported. General Purpose Logging supported. Short self-test routine recommended polling time: ( 1) minutes. Extended self-test routine recommended polling time: ( 18) minutes. Conveyance self-test routine recommended polling time: ( 18) minutes. SCT capabilities: (0x0039) SCT Status supported. SCT Error Recovery Control supported. SCT Feature Control supported. SCT Data Table supported. SMART Attributes Data Structure revision number: 1 Vendor Specific SMART Attributes with Thresholds: ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE 1 Raw_Read_Error_Rate 0x000f 130 130 039 Pre-fail Always - 8477 5 Reallocated_Sector_Ct 0x0033 100 100 001 Pre-fail Always - 0 9 Power_On_Hours 0x0032 100 100 000 Old_age Always - 7004 173 Unknown_Attribute 0x0033 100 100 001 Pre-fail Always - 0 175 Program_Fail_Count_Chip 0x0033 100 100 010 Pre-fail Always - 81604645748 180 Unused_Rsvd_Blk_Cnt_Tot 0x003b 130 130 039 Pre-fail Always - 8477 194 Temperature_Celsius 0x0022 100 100 000 Old_age Always - 29 196 Reallocated_Event_Count 0x0033 100 100 010 Pre-fail Always - 0 SMART Error Log Version: 1 No Errors Logged SMART Self-test log structure revision number 1 No self-tests have been logged. [To run self-tests, use: smartctl -t] SMART Selective self-test log data structure revision number 1 SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS 1 0 0 Not_testing 2 0 0 Not_testing 3 0 0 Not_testing 4 0 0 Not_testing 5 0 0 Not_testing Selective self-test flags (0x0): After scanning selected spans, do NOT read-scan remainder of disk. If Selective self-test is pending on power-up, resume after 0 minute delay. The above only provides legacy SMART information - try 'smartctl -x' for more