smartctl 7.4 2023-08-01 r5530 [x86_64-linux-6.12.86+deb13-amd64] (local build) Copyright (C) 2002-23, Bruce Allen, Christian Franke, www.smartmontools.org === START OF INFORMATION SECTION === Model Family: Intel 730 and DC S35x0/3610/3700 Series SSDs Device Model: INTEL SSDSC2BB480G4 Serial Number: PHWL53710181480QGN LU WWN Device Id: 5 5cd2e4 04c5f8cf1 Firmware Version: D2010370 User Capacity: 480,103,981,056 bytes [480 GB] Sector Sizes: 512 bytes logical, 4096 bytes physical Rotation Rate: Solid State Device Form Factor: 2.5 inches TRIM Command: Available, deterministic, zeroed Device is: In smartctl database 7.3/5528 ATA Version is: ACS-2 T13/2015-D revision 3 SATA Version is: SATA 2.6, 6.0 Gb/s (current: 6.0 Gb/s) Local Time is: Mon Apr 13 19:44:14 2026 UTC SMART support is: Available - device has SMART capability. SMART support is: Enabled === START OF READ SMART DATA SECTION === SMART overall-health self-assessment test result: PASSED General SMART Values: Offline data collection status: (0x02) Offline data collection activity was completed without error. Auto Offline Data Collection: Disabled. Self-test execution status: ( 0) The previous self-test routine completed without error or no self-test has ever been run. Total time to complete Offline data collection: ( 72) seconds. Offline data collection capabilities: (0x79) SMART execute Offline immediate. No Auto Offline data collection support. Suspend Offline collection upon new command. Offline surface scan supported. Self-test supported. Conveyance Self-test supported. Selective Self-test supported. SMART capabilities: (0x0003) Saves SMART data before entering power-saving mode. Supports SMART auto save timer. Error logging capability: (0x01) Error logging supported. General Purpose Logging supported. Short self-test routine recommended polling time: ( 1) minutes. Extended self-test routine recommended polling time: ( 2) minutes. Conveyance self-test routine recommended polling time: ( 2) minutes. SCT capabilities: (0x003d) SCT Status supported. SCT Error Recovery Control supported. SCT Feature Control supported. SCT Data Table supported. SMART Attributes Data Structure revision number: 1 Vendor Specific SMART Attributes with Thresholds: ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE 5 Reallocated_Sector_Ct 0x0032 100 100 000 Old_age Always - 0 9 Power_On_Hours 0x0032 100 100 000 Old_age Always - 55 12 Power_Cycle_Count 0x0032 100 100 000 Old_age Always - 39 170 Available_Reservd_Space 0x0033 100 100 010 Pre-fail Always - 0 171 Program_Fail_Count 0x0032 100 100 000 Old_age Always - 0 172 Erase_Fail_Count 0x0032 100 100 000 Old_age Always - 0 174 Unsafe_Shutdown_Count 0x0032 100 100 000 Old_age Always - 30 175 Power_Loss_Cap_Test 0x0033 100 100 010 Pre-fail Always - 683 (1 6) 183 SATA_Downshift_Count 0x0032 100 100 000 Old_age Always - 0 184 End-to-End_Error 0x0033 100 100 090 Pre-fail Always - 0 187 Reported_Uncorrect 0x0032 100 100 000 Old_age Always - 0 190 Temperature_Case 0x0022 086 079 000 Old_age Always - 14 (Min/Max 11/14) 192 Unsafe_Shutdown_Count 0x0032 100 100 000 Old_age Always - 30 194 Temperature_Internal 0x0022 100 100 000 Old_age Always - 25 197 Current_Pending_Sector 0x0032 100 100 000 Old_age Always - 0 199 CRC_Error_Count 0x003e 100 100 000 Old_age Always - 0 225 Host_Writes_32MiB 0x0032 100 100 000 Old_age Always - 1907 226 Workld_Media_Wear_Indic 0x0032 100 100 000 Old_age Always - 2150 227 Workld_Host_Reads_Perc 0x0032 100 100 000 Old_age Always - 93 228 Workload_Minutes 0x0032 100 100 000 Old_age Always - 2197334 232 Available_Reservd_Space 0x0033 100 100 010 Pre-fail Always - 0 233 Media_Wearout_Indicator 0x0032 100 100 000 Old_age Always - 0 234 Thermal_Throttle 0x0032 100 100 000 Old_age Always - 0/0 241 Host_Writes_32MiB 0x0032 100 100 000 Old_age Always - 1907 242 Host_Reads_32MiB 0x0032 100 100 000 Old_age Always - 437 SMART Error Log Version: 1 No Errors Logged SMART Self-test log structure revision number 1 Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error # 1 Conveyance offline Completed without error 00% 36514 - SMART Selective self-test log data structure revision number 1 SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS 1 0 0 Not_testing 2 0 0 Not_testing 3 0 0 Not_testing 4 0 0 Not_testing 5 0 0 Not_testing Selective self-test flags (0x0): After scanning selected spans, do NOT read-scan remainder of disk. If Selective self-test is pending on power-up, resume after 0 minute delay. The above only provides legacy SMART information - try 'smartctl -x' for more