smartctl 7.4 2023-08-01 r5530 [x86_64-linux-6.12.86+deb13-amd64] (local build) Copyright (C) 2002-23, Bruce Allen, Christian Franke, www.smartmontools.org === START OF INFORMATION SECTION === Model Family: Dell Certified Intel S4x00/D3-S4x10 Series SSDs Device Model: SSDSC2KB960G7R Serial Number: BTYS84910MF9960CGN LU WWN Device Id: 5 5cd2e4 15022a2a7 Add. Product Id: DELL(tm) Firmware Version: SCV1DL5C User Capacity: 960,197,124,096 bytes [960 GB] Sector Sizes: 512 bytes logical, 4096 bytes physical Rotation Rate: Solid State Device Form Factor: 2.5 inches TRIM Command: Available, deterministic, zeroed Device is: In smartctl database 7.3/5528 ATA Version is: ACS-3 T13/2161-D revision 5 SATA Version is: SATA 3.2, 6.0 Gb/s (current: 6.0 Gb/s) Local Time is: Mon Apr 13 19:39:51 2026 UTC SMART support is: Available - device has SMART capability. SMART support is: Enabled === START OF READ SMART DATA SECTION === SMART overall-health self-assessment test result: PASSED General SMART Values: Offline data collection status: (0x02) Offline data collection activity was completed without error. Auto Offline Data Collection: Disabled. Self-test execution status: ( 0) The previous self-test routine completed without error or no self-test has ever been run. Total time to complete Offline data collection: ( 2) seconds. Offline data collection capabilities: (0x79) SMART execute Offline immediate. No Auto Offline data collection support. Suspend Offline collection upon new command. Offline surface scan supported. Self-test supported. Conveyance Self-test supported. Selective Self-test supported. SMART capabilities: (0x0003) Saves SMART data before entering power-saving mode. Supports SMART auto save timer. Error logging capability: (0x01) Error logging supported. General Purpose Logging supported. Short self-test routine recommended polling time: ( 1) minutes. Extended self-test routine recommended polling time: ( 60) minutes. Conveyance self-test routine recommended polling time: ( 60) minutes. SCT capabilities: (0x003d) SCT Status supported. SCT Error Recovery Control supported. SCT Feature Control supported. SCT Data Table supported. SMART Attributes Data Structure revision number: 1 Vendor Specific SMART Attributes with Thresholds: ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE 1 Raw_Read_Error_Rate 0x000e 130 130 039 Old_age Always - 21509 5 Reallocated_Sector_Ct 0x0033 100 100 001 Pre-fail Always - 0 9 Power_On_Hours 0x0032 100 100 000 Old_age Always - 39092 12 Power_Cycle_Count 0x0032 100 100 000 Old_age Always - 46 13 Read_Soft_Error_Rate 0x001e 130 130 000 Old_age Always - 21509 170 Available_Reservd_Space 0x0033 100 100 010 Pre-fail Always - 0 174 Unsafe_Shutdown_Count 0x0032 100 100 000 Old_age Always - 39 179 Used_Rsvd_Blk_Cnt_Tot 0x0033 100 100 010 Pre-fail Always - 0 180 Unused_Rsvd_Blk_Cnt_Tot 0x0032 100 100 000 Old_age Always - 11572 181 Program_Fail_Cnt_Total 0x003a 100 100 000 Old_age Always - 0 182 Erase_Fail_Count_Total 0x003a 100 100 000 Old_age Always - 0 184 End-to-End_Error 0x0032 100 100 000 Old_age Always - 0 194 Temperature_Celsius 0x0022 100 100 000 Old_age Always - 22 195 Uncorrectable_Error_Cnt 0x0032 100 100 000 Old_age Always - 0 197 Current_Pending_Sector 0x0012 100 100 000 Old_age Always - 0 198 Offline_Uncorrectable 0x0010 100 100 000 Old_age Offline - 0 199 CRC_Error_Count 0x003e 100 100 000 Old_age Always - 0 201 Power_Loss_Cap_Test 0x0033 100 100 010 Pre-fail Always - 2563 (282 5430) 202 End_of_Life 0x0027 100 100 000 Pre-fail Always - 0 225 Host_Writes_32MiB 0x0032 100 100 000 Old_age Always - 59219 226 Workld_Media_Wear_Indic 0x0032 100 100 000 Old_age Always - 81 227 Workld_Host_Reads_Perc 0x0032 100 100 000 Old_age Always - 75 228 Workload_Minutes 0x0032 100 100 000 Old_age Always - 2345171 232 Available_Reservd_Space 0x0033 100 100 010 Pre-fail Always - 0 233 Total_LBAs_Written 0x0032 100 100 000 Old_age Always - 59219 234 Thermal_Throttle_Status 0x0032 100 100 000 Old_age Always - 0/0 241 Total_LBAs_Written 0x0032 100 100 000 Old_age Always - 59219 242 Total_LBAs_Read 0x0032 100 100 000 Old_age Always - 244200 245 Percent_Life_Remaining 0x0032 100 100 000 Old_age Always - 100 SMART Error Log not supported SMART Self-test log structure revision number 1 Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error # 1 Short offline Completed without error 00% 39001 - # 2 Extended offline Completed without error 00% 1 - # 3 Short offline Aborted by host 00% 1 - # 4 Short offline Completed without error 00% 1 - # 5 Vendor (0x40) Aborted by host 00% 1 - Read SMART Selective Self-test Log failed: scsi error aborted command The above only provides legacy SMART information - try 'smartctl -x' for more